Δημοσίευση

Quantifying the effect of side branches in endothelial shear stress estimates.

ΤίτλοςQuantifying the effect of side branches in endothelial shear stress estimates.
Publication TypeJournal Article
Year of Publication2016
AuthorsGiannopoulos, A. A., Chatzizisis Y. S., Maurovich-Horvat P., Antoniadis A. P., Hoffmann U., Steigner M. L., Rybicki F. J., & Mitsouras D.
JournalAtherosclerosis
Volume251
Pagination213-218
Date Published2016 08
ISSN1879-1484
Λέξεις κλειδιάAtherosclerosis, Coronary Angiography, Coronary Artery Disease, Coronary Circulation, Coronary Vessels, Disease Progression, Endothelium, Vascular, Heart, Hemodynamics, Humans, Hydrodynamics, Image Processing, Computer-Assisted, Imaging, Three-Dimensional, Plaque, Atherosclerotic, Predictive Value of Tests, Reproducibility of Results, Sensitivity and Specificity, Shear Strength, Software, Stress, Mechanical
Abstract

BACKGROUND AND AIMS: Low and high endothelial shear stress (ESS) is associated with coronary atherosclerosis progression and high-risk plaque features. Coronary ESS is currently assessed via computational fluid dynamic (CFD) simulation of coronary blood flow in the lumen geometry determined from invasive imaging such as intravascular ultrasound and optical coherence tomography. This process typically omits side branches of the target vessel in the CFD model as invasive imaging of those vessels is not usually clinically-indicated. The purpose of this study was to determine the extent to which this simplification affects the determination of those regions of the coronary endothelium subjected to pathologic ESS.METHODS: We determined the diagnostic accuracy of ESS profiling without side branches to detect pathologic ESS in the major coronary arteries of 5 hearts imaged ex vivo with computed tomography angiography (CTA). ESS of the three major coronary arteries was calculated both without (test model), and with (reference model) inclusion of all side branches >1.5 mm in diameter, using previously-validated CFD approaches. Diagnostic test characteristics (accuracy, sensitivity, specificity and negative and positive predictive value [NPV/PPV]) with respect to the reference model were assessed for both the entire length as well as only the proximal portion of each major coronary artery, where the majority of high-risk plaques occur.RESULTS: Using the model without side branches overall accuracy, sensitivity, specificity, NPV and PPV were 83.4%, 54.0%, 96%, 95.9% and 55.1%, respectively to detect low ESS, and 87.0%, 67.7%, 90.7%, 93.7% and 57.5%, respectively to detect high ESS. When considering only the proximal arteries, test characteristics differed for low and high ESS, with low sensitivity (67.7%) and high specificity (90.7%) to detect low ESS, and low sensitivity (44.7%) and high specificity (95.5%) to detect high ESS.CONCLUSIONS: The exclusion of side branches in ESS vascular profiling studies greatly reduces the ability to detect regions of the major coronary arteries subjected to pathologic ESS. Single-conduit models can in general only be used to rule out pathologic ESS.

DOI10.1016/j.atherosclerosis.2016.06.038
Alternate JournalAtherosclerosis
PubMed ID27372207
PubMed Central IDPMC4983229
Grant ListK01 EB015868 / EB / NIBIB NIH HHS / United States

Επικοινωνία

Τμήμα Ιατρικής, Πανεπιστημιούπολη ΑΠΘ, T.K. 54124, Θεσσαλονίκη
 

Συνδεθείτε

Το τμήμα Ιατρικής στα κοινωνικά δίκτυα.
Ακολουθήστε μας ή συνδεθείτε μαζί μας.