The english version of the website is under development. Wherever text appears in Greek, it means it has not been translated yet.

Δημοσίευση

A minimally invasive method for clinical trans-diaphragmatic pressure measurement in anaesthetized dogs.

TitleA minimally invasive method for clinical trans-diaphragmatic pressure measurement in anaesthetized dogs.
Publication TypeJournal Article
Year of Publication2014
AuthorsPavlidou, K., Savvas I., Moens Y., Vasilakos D., & Raptopoulos D.
JournalVet Anaesth Analg
Volume41
Issue3
Pagination278-83
Date Published2014 May
ISSN1467-2995
KeywordsAnesthesia, General, Animals, Diaphragm, Dogs, Monitoring, Physiologic, Pilot Projects, Pressure
Abstract

OBJECTIVE: To measure trans-diaphragmatic pressures, as an indication of diaphragmatic contractility, in anaesthetized dogs breathing normally, or during inspiratory obstruction (Mueller's manoeuvre) in order to assess if the method is practicable for use in clinical circumstances.STUDY DESIGN: Pilot study.ANIMALS: Twenty eight client-owned dogs, ASA I or II, 1-10 years old, 5-30 kg bodyweight, which required anaesthesia for surgery, and were to be positioned in lateral recumbency.METHODS: Following a standardized regimen of premedication and anaesthetic induction, anaesthesia was stabilized and maintained with isoflurane. Two commercially available balloon catheters were introduced orally, and advanced, one into the stomach and one into the mid-third of the oesophagus. Oesophageal and gastric pressures were measured from these catheters, and trans-diaphragmatic pressure (Pdi ) calculated and recorded continuously. At three separate time points during anaesthesia, for one breath, inspiration was obstructed (Mueller's manoeuvre) and Pdi was measured.RESULTS: Placement of the catheters in the stomach was not easy, and failed in three cases. In five dogs, their size resulted in failure of correct placement of catheters. Good traces of all three pressures reflecting respiratory cycles were obtained from 20 dogs. During normal spontaneous breathing (mean ± SD [range]) Pdi was 5 ± 2.1 (3-10) mmHg. During Mueller's manoeuvre, Pdi was 14.6 ± 4.5 (9-21) mmHg. Abnormal waveforms were seen included cardiac oscillations (five dogs), inadequate intra-gastric pressure tracing (one dog), deflections with a double peak (one dog), and multiple artifacts when there was increased heart rate and tachypnoea (two dogs in response to surgery).CONCLUSIONS AND CLINICAL RELEVANCE: Measurement of trans-diaphragmatic pressure with balloon catheters was practicable in suitably sized dogs anaesthetized for clinical purposes and might be a useful tool in the assessment of diaphragmatic function. A range of catheters are required if the technique is to work in all dogs.

DOI10.1111/vaa.12073
Alternate JournalVet Anaesth Analg
PubMed ID23902540

Contact

Secretariat of the School of Medicine
 

Connect

School of Medicine's presence in social networks
Follow Us or Connect with us.