The english version of the website is under development. Wherever text appears in Greek, it means it has not been translated yet.

Δημοσίευση

High performance MRI simulations of motion on multi-GPU systems.

TitleHigh performance MRI simulations of motion on multi-GPU systems.
Publication TypeJournal Article
Year of Publication2014
AuthorsXanthis, C. G., Venetis I. E., & Aletras A. H.
JournalJ Cardiovasc Magn Reson
Volume16
Pagination48
Date Published2014
ISSN1532-429X
KeywordsAlgorithms, Artifacts, Blood Flow Velocity, Computer Simulation, Coronary Circulation, Heart, Heart Rate, Humans, Image Interpretation, Computer-Assisted, Magnetic Resonance Imaging, Cine, Models, Anatomic, Models, Cardiovascular, Motion, Myocardial Contraction, Predictive Value of Tests, Reproducibility of Results, Respiratory Rate, Software, Time Factors
Abstract

BACKGROUND: MRI physics simulators have been developed in the past for optimizing imaging protocols and for training purposes. However, these simulators have only addressed motion within a limited scope. The purpose of this study was the incorporation of realistic motion, such as cardiac motion, respiratory motion and flow, within MRI simulations in a high performance multi-GPU environment.METHODS: Three different motion models were introduced in the Magnetic Resonance Imaging SIMULator (MRISIMUL) of this study: cardiac motion, respiratory motion and flow. Simulation of a simple Gradient Echo pulse sequence and a CINE pulse sequence on the corresponding anatomical model was performed. Myocardial tagging was also investigated. In pulse sequence design, software crushers were introduced to accommodate the long execution times in order to avoid spurious echoes formation. The displacement of the anatomical model isochromats was calculated within the Graphics Processing Unit (GPU) kernel for every timestep of the pulse sequence. Experiments that would allow simulation of custom anatomical and motion models were also performed. Last, simulations of motion with MRISIMUL on single-node and multi-node multi-GPU systems were examined.RESULTS: Gradient Echo and CINE images of the three motion models were produced and motion-related artifacts were demonstrated. The temporal evolution of the contractility of the heart was presented through the application of myocardial tagging. Better simulation performance and image quality were presented through the introduction of software crushers without the need to further increase the computational load and GPU resources. Last, MRISIMUL demonstrated an almost linear scalable performance with the increasing number of available GPU cards, in both single-node and multi-node multi-GPU computer systems.CONCLUSIONS: MRISIMUL is the first MR physics simulator to have implemented motion with a 3D large computational load on a single computer multi-GPU configuration. The incorporation of realistic motion models, such as cardiac motion, respiratory motion and flow may benefit the design and optimization of existing or new MR pulse sequences, protocols and algorithms, which examine motion related MR applications.

DOI10.1186/1532-429X-16-48
Alternate JournalJ Cardiovasc Magn Reson
PubMed ID24996972
PubMed Central IDPMC4107941

Contact

Secretariat of the School of Medicine
 

Connect

School of Medicine's presence in social networks
Follow Us or Connect with us.